"M-Flex 402" PN# HFE-160D. FEP outer Jacket with a braid and foil shield. Solid PTFE dielectric w/ a silver plated copper clad steel center conductor. Cable sized to accept 141 semi-rigid type connectors.

 


HFE160D

Flexible Microwave Cable


MECHANICAL CHARACTERISTICS

Jacket Diameter, inch (mm) 0.162  (4.115)
Outer Shield Diameter, inch (mm) 0.140  (3.560)
Dielectric Diameter, inch (mm) 0.120  (3.048)
Center Conductor Diameter, inch (mm) 0.036  (0.914)
Minimum Bend Radius, inch (mm) 0.500  (12.700)
Weight, grams/ft. (grams/meter) 13.180  (43.250)

ELECTRICAL CHARACTERISTICS

Impedance, ohms  
Frequency Range DC-18
Velocity of Propagation 0.705
Capacitance, pF/ft. (pF/meter) 29.3  (96.1)
Shielding Effectiveness, dB @ 1GHz >90dB
Maximum Insertion Loss, dB/ ft. (dB/meter) Frequency Insertion Loss
0.5 GHz
1.0 GHz
10.0 GHz
18.0 GHz
0.090 (0.295)
0.120 (0.394)
0.450 (1.476)
0.650 (2.133)
Power Handling See Graph
Maximum Voltage, VRMS 2000

ENVIRONMENTAL CHARACTERISTICS

Temperature Range, Celsius -65 to +125

MATERIALS

Outer jacket FEP
Braid SPC Braid
Outer Shield Silver plated copper tape
Dielectric PTFE
Center Conductor Solid SPCW