UT-141C-35
|
Semi-Rigid Coaxial Cable
|
|
MECHANICAL CHARACTERISTICS
|
|
|
Outer Conductor Diameter, inch (mm) |
0.141+/-0.001 (3.581+/-0.0254) |
Dielectric Diameter, inch (mm) |
0.117 (2.97) |
Center Conductor Diameter, inch (mm) |
0.0508+/-0.001 (1.29+/-0.0254) |
Maximum Length, feet (meters) |
20 (6.1) |
Minimum Inside Bend Radius, inch (mm) |
0.188 (4.775) |
Weight, pounds/100 ft. (kg/100 meters) |
3.5 (5.21) |
|
ELECTRICAL CHARACTERISTICS
|
|
|
Impedance, ohms |
35+/-1.0 |
Frequency Range GHz |
DC-31 |
Velocity of Propagation % |
70 |
Capacitance, pF/ft. (pF/meter) |
41.5 (136) |
Typical Insertion Loss, dB/ft. (dB/meter) and Average Power Handling, Watts CW at 20 degrees Celsius and Sea level |
Frequency |
Insertion Loss |
Power |
0.5 GHz 1.0 GHz 5.0 GHz 10.0 GHz 20.0 GHz |
0.09 (0.28) 0.12 (0.41) 0.30 (0.99) 0.45 (1.48) 0.69 (2.25) |
552.4 384.6 161.5 109.2 72.7 |
Corona Extinction Voltage, VRMS @ 60 Hz |
1500 |
Voltage Withstand, VRMS @ 60 Hz |
3000 |
|
ENVIRONMENTAL CHARACTERISTICS
|
|
|
Outer Conductor Integrity Temperature, Deg Celsius |
175 |
Maximum Operating Temperature, Deg Celsius |
125 |
|
Outer Conductor |
Copper |
Dielectric |
PTFE |
Center Conductor |
SPC |
|
|