UT-062-18-TP/CE18062
|
Semi-Rigid Coaxial Cable
|
|
MECHANICAL CHARACTERISTICS
|
|
|
Outer Conductor Diameter, inch (mm) |
0.062+0.002 / -0.001 (1.575+0.0508/-0.0254) |
Dielectric Diameter, inch (mm) |
0.049 (1.245) |
Center Conductor Diameter, inch (mm) |
0.032+/-0.0005 (0.813+/-0.0127) |
Maximum Length, feet (meters) |
25 (7.62) |
Minimum Inside Bend Radius, inch (mm) |
0.125 (3.175) |
Weight, pounds/100 ft. (kg/100 meters) |
0.82 (1.23) |
|
ELECTRICAL CHARACTERISTICS
|
|
|
Impedance, ohms |
18+/-2.0 |
Frequency Range GHz |
DC-65 |
Velocity of Propagation % |
70 |
Capacitance, pF/ft. (pF/meter) |
80.6 (264.5) |
Typical Insertion Loss, dB/ft. (dB/meter) and Average Power Handling, Watts CW at 20 degrees Celsius and Sea level |
Frequency |
Insertion Loss |
Power |
0.5 GHz 1.0 GHz 5.0 GHz 10.0 GHz 20.0 GHz |
0.30 (0.98) 0.42 (1.39) 0.97 (3.18) 1.40 (4.58) 2.02 (6.64) |
55.8 39.3 17.2 12 8.3 |
Corona Extinction Voltage, VRMS @ 60 Hz |
1100 |
Voltage Withstand, VRMS @ 60 Hz |
2000 |
|
ENVIRONMENTAL CHARACTERISTICS
|
|
|
Outer Conductor Integrity Temperature, Deg Celsius |
175 |
Maximum Operating Temperature, Deg Celsius |
150 |
|
Outer Conductor |
Tin plated Copper |
Dielectric |
PTFE |
Center Conductor |
SPCW |
|
|