 | UT-070C | 
| Semi-Rigid Coaxial Cable | 
| 
| 
 | MECHANICAL CHARACTERISTICS | 
 |  | 
| Outer Conductor Diameter, inch (mm) | 0.070+/-0.001  (1.778+/-0.0254) | 
| Dielectric Diameter, inch (mm) | 0.059  (1.499) | 
| Center Conductor Diameter, inch (mm) | 0.0179+/-0.0005  (0.455+/-0.0127) | 
| Maximum Length, feet (meters) | 20  (6.1) | 
| Minimum Inside Bend Radius, inch (mm) | 0.125  (3.175) | 
| Weight, pounds/100 ft. (kg/100 meters) | 0.77  (1.15) | 
| 
| 
 | ELECTRICAL CHARACTERISTICS | 
 |  | 
| Impedance, ohms | 50+/-1.0 | 
| Frequency Range GHz | DC-68 | 
| Velocity of Propagation % | 70 | 
| Capacitance, pF/ft. (pF/meter) | 29 (95.1) | 
| Typical Insertion Loss, dB/ft. (dB/meter) and Average Power Handling, Watts CW at 20
 degrees Celsius and Sea level
 | Frequency | Insertion Loss | Power | 
| 0.5 GHz 1.0 GHz
 5.0 GHz
 10.0 GHz
 20.0 GHz
 | 0.15 (0.50) 0.22 (0.71)
 0.51 (1.66)
 0.75 (2.44)
 1.10 (3.62)
 | 124 86.9
 37.4
 25.7
 17.5
 | 
| Corona Extinction Voltage, VRMS @ 60 Hz | 1200 | 
| Voltage Withstand, VRMS @ 60 Hz | 2300 | 
| 
| 
 | ENVIRONMENTAL CHARACTERISTICS | 
 |  | 
| Outer Conductor Integrity Temperature, Deg Celsius | 135 | 
| Maximum Operating Temperature, Deg Celsius | 100 | 
|  | 
| Outer Conductor | Copper | 
| Dielectric | PTFE | 
| Center Conductor | SPC | 
|  | 
|  |