UT-141-HA-TP-M17 (M17/130-00001)
|
|
Semi-Rigid Coaxial Cable
|
|
MECHANICAL CHARACTERISTICS
|
|
|
| Outer Conductor Diameter, inch (mm) |
0.141+0.002 / -0.001 (3.581+0.0508 / -0.0254) |
| Dielectric Diameter, inch (mm) |
0.1175 (2.985) |
| Center Conductor Diameter, inch (mm) |
0.0362+/-0.0007 (0.919+/-0.0178) |
| Maximum Length, feet (meters) |
20 (6.1) |
| Minimum Inside Bend Radius, inch (mm) |
0.25 (6.35) |
| Weight, pounds/100 ft. (kg/100 meters) |
3.51 (5.22) |
|
ELECTRICAL CHARACTERISTICS
|
|
|
| Impedance, ohms |
50+/-1.0 |
| Frequency Range GHz |
DC-20 |
| Velocity of Propagation % |
70 |
| Capacitance, pF/ft. (pF/meter) |
29.9 (98.1) |
Typical Insertion Loss, dB/ft. (dB/meter) and Average Power Handling, Watts CW at 20 degrees Celsius and Sea level |
Frequency |
Insertion Loss |
Power |
0.5 GHz 1.0 GHz 5.0 GHz 10.0 GHz 20.0 GHz |
0.08 (0.26) 0.12 (0.39) 0.29 (0.95) 0.45 (1.48) 0.70 (2.30) |
600 450 180 120 70 |
| Corona Extinction Voltage, VRMS @ 60 Hz |
1900 |
| Voltage Withstand, VRMS @ 60 Hz |
5000 |
|
ENVIRONMENTAL CHARACTERISTICS
|
|
|
| Outer Conductor Integrity Temperature, Deg Celsius |
175 |
| Maximum Operating Temperature, Deg Celsius |
125 |
|
|
| Outer Conductor |
Tin plated Copper |
| Dielectric |
PTFE |
| Center Conductor |
SPCW |
|
|
 |