UT-090C-35
|
Semi-Rigid Coaxial Cable
|
|
MECHANICAL CHARACTERISTICS
|
|
|
Outer Conductor Diameter, inch (mm) |
0.090+/-0.001 (2.286+/-0.0254) |
Dielectric Diameter, inch (mm) |
0.074 (1.88) |
Center Conductor Diameter, inch (mm) |
0.032+/-0.001 (0.813+/-0.0254) |
Maximum Length, feet (meters) |
20 (6.1) |
Minimum Inside Bend Radius, inch (mm) |
0.125 (3.175) |
Weight, pounds/100 ft. (kg/100 meters) |
1.44 (2.14) |
|
ELECTRICAL CHARACTERISTICS
|
|
|
Impedance, ohms |
35+/-1.0 |
Frequency Range GHz |
DC-49 |
Velocity of Propagation % |
70 |
Capacitance, pF/ft. (pF/meter) |
41.5 (136) |
Typical Insertion Loss, dB/ft. (dB/meter) and Average Power Handling, Watts CW at 20 degrees Celsius and Sea level |
Frequency |
Insertion Loss |
Power |
0.5 GHz 1.0 GHz 5.0 GHz 10.0 GHz 20.0 GHz |
0.13 (0.44) 0.19 (0.63) 0.45 (1.47) 0.66 (2.17) 0.98 (3.23) |
200.6 140.4 60.2 41.3 28 |
Corona Extinction Voltage, VRMS @ 60 Hz |
1500 |
Voltage Withstand, VRMS @ 60 Hz |
2500 |
|
ENVIRONMENTAL CHARACTERISTICS
|
|
|
Outer Conductor Integrity Temperature, Deg Celsius |
150 |
Maximum Operating Temperature, Deg Celsius |
125 |
|
Outer Conductor |
Copper |
Dielectric |
PTFE |
Center Conductor |
SPC |
|
 |