UT-034-SP
|
Semi-Rigid Coaxial Cable
|
|
MECHANICAL CHARACTERISTICS
|
|
|
Outer Conductor Diameter, inch (mm) |
0.034+0.002 / -0.001 (0.864+0.0508 /-0.0254) |
Dielectric Diameter, inch (mm) |
0.026 (0.66) |
Center Conductor Diameter, inch (mm) |
0.008+/-0.0005 (0.203+/-0.0127) |
Maximum Length, feet (meters) |
15 (4.57) |
Minimum Inside Bend Radius, inch (mm) |
0.05 (1.27) |
Weight, pounds/100 ft. (kg/100 meters) |
0.21 (0.31) |
|
ELECTRICAL CHARACTERISTICS
|
|
|
Impedance, ohms |
50+/-1.5 |
Frequency Range GHz |
DC-155 |
Velocity of Propagation % |
70 |
Capacitance, pF/ft. (pF/meter) |
29 (95.1) |
Typical Insertion Loss, dB/ft. (dB/meter) and Average Power Handling, Watts CW at 20 degrees Celsius and Sea level |
Frequency |
Insertion Loss |
Power |
0.5 GHz 1.0 GHz 5.0 GHz 10.0 GHz 20.0 GHz |
0.34 (1.12) 0.48 (1.58) 1.10 (3.62) 1.59 (5.20) 2.29 (7.52) |
28.5 20 8.8 6.2 4.3 |
Corona Extinction Voltage, VRMS @ 60 Hz |
750 |
Voltage Withstand, VRMS @ 60 Hz |
2000 |
|
ENVIRONMENTAL CHARACTERISTICS
|
|
|
Outer Conductor Integrity Temperature, Deg Celsius |
150 |
Maximum Operating Temperature, Deg Celsius |
125 |
|
Outer Conductor |
Silver plated Copper |
Dielectric |
PTFE |
Center Conductor |
SPCW |
|
|